Forced Circulation Package Series (EFCPA)

////Forced Circulation Package Series (EFCPA)

Forced Circulation Package Series (EFCPA)

  • EFCPA Forced circulation package series is a solar water heating system for residential and commercial applications with high efficiency and better energy savings.
  • The EFCP system includes Flat Plate Solar Thermal Collectors with Aluminium Absorber with High Absorbance
  • Vertical Floor Standing Solar Storage Tank With Single Heat Exchanger with Incoloy 840 Back up Heating Element.
  • Enameled Steel Inner Tank With 7 Bar Maximum Operating Pressure.
  • HCFC Free Polyurethane Insulation.
  • Solar Pump Station with Integrated Controller.
Data Sheet
Inquiry?
Support

Application

  •  Residential & Commercial – Hot water.

Features

  • Eautek Forced Circulation Package Series are available in various capacities from 300L to 5000L to suit all types of Residential and Commercial needs.
  • CE Certified Solar Thermal Collector with 2m2 gross area and high Absorbance.
  • Vertical Floor Standing Solar Storage Tank with Maximum Operating Pressure of 7 bar and Test pressure is 10 Bar.
  • Enamelled steel inner tank with glass finish according to DIN 4753 Norm.
  • HCFC-Free high-density polyurethane foam for optimum insulation.

Benefits

  • Incoloy 840 Heating Element with adjustable thermostat sensor, enabling effective and precise temperature setting and built-in safety cut-off device.
  • Equipped with Magnesium Anode for better and long protection against corrosion.
  • Factory tested in-line safety valve with drain cock and safety screw and avoid overheating.
  • IP66 Rated Weather Resistant GI with Special Polymer Paint.
  • Solar pump station with integrated controller.

Data Table

Dimensions (LXWXH) 2000X1000X95mm
Weight 30 Kg
Sealing EPDM
Gross Area 2 m2
Absorber Area 1.8m2
Absorber Material Aluminium
Absorber Thickness 0.4mm
Absorbtance 95%
Emittance 5%
Welding Method Laser
Diameter Of Absorber Tube 8
Absorber Tube Wall Thickness 0.6
Diameter Of Header Tube 22mm
Header Tube Wall Thickness 0.6mm
Number Of Tube 7
Tube Pitch 110mm
Glass Material Low iron, tempered glass
Transmittance Of Glass 92%
Thickness Of Glass 4mm
Insulation Material Fibre Glass
Density Of Wool 36 Kg/m3
Thickness Of Wool 50mm
Stagnation Temperature 180 Deg. C
Maximum Operation Pressure 7.5 Bar
Test Pressure 12 Bar
Pipe Material Copper
Casing Material Aluminium
Casing Thickness 1.2mm
Base Sheeting Mounting Aluminium
Thermal Efficiency 80%
Heat loss Coefficient a1 2.889 W/m2. K
Heat loss Coefficient a2 0.026 W/m2. K