Forced Circulation Package Series (EFCPA)
-
EFCPA Forced circulation package series is a solar water heating system for residential and commercial applications with high efficiency and better energy savings.
-
The EFCP system includes Flat Plate Solar Thermal Collectors with Aluminium Absorber with High Absorbance
-
Vertical Floor Standing Solar Storage Tank With Single Heat Exchanger with Incoloy 840 Back up Heating Element.
-
Enameled Steel Inner Tank With 7 Bar Maximum Operating Pressure.
-
HCFC Free Polyurethane Insulation.
-
Solar Pump Station with Integrated Controller.
Application
-
Residential & Commercial – Hot water.
Features
-
Eautek Forced Circulation Package Series are available in various capacities from 300L to 5000L to suit all types of Residential and Commercial needs.
-
CE Certified Solar Thermal Collector with 2m2 gross area and high Absorbance.
-
Vertical Floor Standing Solar Storage Tank with Maximum Operating Pressure of 7 bar and Test pressure is 10 Bar.
-
Enamelled steel inner tank with glass finish according to DIN 4753 Norm.
-
HCFC-Free high-density polyurethane foam for optimum insulation.
Benefits
-
Incoloy 840 Heating Element with adjustable thermostat sensor, enabling effective and precise temperature setting and built-in safety cut-off device.
-
Equipped with Magnesium Anode for better and long protection against corrosion.
-
Factory tested in-line safety valve with drain cock and safety screw and avoid overheating.
-
IP66 Rated Weather Resistant GI with Special Polymer Paint.
-
Solar pump station with integrated controller.
Data Table
Dimensions (LXWXH) | 2000X1000X95mm |
---|---|
Weight | 30 Kg |
Sealing | EPDM |
Gross Area | 2 m2 |
Absorber Area | 1.8m2 |
Absorber Material | Aluminium |
Absorber Thickness | 0.4mm |
Absorbtance | 95% |
Emittance | 5% |
Welding Method | Laser |
Diameter Of Absorber Tube | 8 |
Absorber Tube Wall Thickness | 0.6 |
Diameter Of Header Tube | 22mm |
Header Tube Wall Thickness | 0.6mm |
Number Of Tube | 7 |
Tube Pitch | 110mm |
Glass Material | Low iron, tempered glass |
Transmittance Of Glass | 92% |
Thickness Of Glass | 4mm |
Insulation Material | Fibre Glass |
Density Of Wool | 36 Kg/m3 |
Thickness Of Wool | 50mm |
Stagnation Temperature | 180 Deg. C |
Maximum Operation Pressure | 7.5 Bar |
Test Pressure | 12 Bar |
Pipe Material | Copper |
Casing Material | Aluminium |
Casing Thickness | 1.2mm |
Base Sheeting Mounting | Aluminium |
Thermal Efficiency | 80% |
Heat loss Coefficient a1 | 2.889 W/m2. K |